Trace NOx analyzer

Overview


Serinus 40 Trace NOX analyzer

The new Serinus 40 Trace NOX analyzer is the next generation in gas monitoring technology.

no/no2/nox analyzer serinus

The Serinus 40 Trace NOX analyzer uses gas phase chemiluminescence technology to measure background levels of NOX in ambient air (LDL <0.4ppb, Range 0-20ppm). Combining several new technical advances and innovative features, the Serinus delivers Ecotech's renowned performance and excellent value.

 

The Serinus 40 Trace NOX analyzer is designed with modern technology and contains advanced communications for use in remote communication and instantaneous data display on the internet.

Features

  • Based on EN approved technology (EN14211:2005)
  • More affordable to purchase, operate and maintain
  • New zero volume fittings and flexible Teflon tubing improves system integrity
  • Catalytic ozone destroyer eliminates need to replace charcoal scrubbers
  • New intuitive menu system with quick menu
  • Internal memory stores 8 years of data
  • Reduced power usage, lower carbon footprint
  • Improved remote instrument diagnostics and maintenance functions
  • New dual particulate filter can reduce scheduled maintenance calls by up to 50%

Specifications

Serinus 40 Trace NOX analyzer

Range:

LDL:

Noise:

Temperature range:

Sample flow rate:

Weight:

 

Dimensions:

Power:

0-2000 ppb

< 50 ppt

< 25 ppt

0 to 40°C

340 cc/min (optional 680cc/min)

21.2 kg (bench)

16.2 kg (rack)

440 x 178 x 620 mm (w x h x d), 3.5 RU

99-132 VAC, 198-264 VAC 47-63 Hz

Data Logging:

  • Internal memory that stores data in the following formats:
  • Instantaneous data from: 1, 3, 5, 10, 30, or 60 minute intervals
    • Average data from: 1, 3, 5, 10, 15, 30 minutes, 1, 4, 8, 12, or 24 hours
    • Data storage of 8 years, 1 minute data on 1 gigabyte memory


Accessories

Serinus 40 Trace NOX analyzer

Accessories

Pt No.

Rack mount kit assembly (19”) E020102
Internal low power pump (Max 6 watts) E020104
External PUMP 230/240 VAC/50Hz P030004
External PUMP 110/115 VAC/60 Hz P030005
Dual sample filter (installed) E020100
Test lamp (installed) E020103
Bench top lid (installed) E020110
High pressure calibration (installed) E020108 (Span)
E020109 (zero)

Spares/Consumables

Pt No.

Molycon assembly, NO2 to NO converter H011105
Dessicant, 5 gram pack (2 required) C050014
Particulate filter (50 p.ce) F010004
Annual Maintenance Kit E020203
Filter unit disposable F010005
Gasket, pressure sensor H010037
Extraction tool orifice and filter H010046