Trace CO analyzer

Overview

Serinus 30 Trace CO analyzer

The new Serinus 30 Trace CO analyzer is the next generation in gas monitoring technology.

co analyzer serinus

The Serinus 30 Trace CO analyzer uses proven gas filter correlation technology to measure CO in ambient air (LDL <20 ppb, Range 0-100 ppm). Combining several new technical advances and innovative features, the Serinus delivers Ecotech's renowned performance and excellent value.

 

The Serinus 30 CO analyzer is designed with modern technology and contains advanced communications for use in remote communication and instantaneous data display on the internet.

Features

  • Based on U.S. EPA approved (EQOA80987) and EN approved (Sira MC 100166/00) technology
  • More affordable to purchase, operate and maintain
  • New zero volume fittings and flexible Teflon tubing improves system integrity
  • New intuitive menu system with quick menu
  • Internal memory stores 8 years of data
  • Reduced power usage, lower carbon footprint
  • Improved remote instrument diagnostics and maintenance functions
  • New dual particulate filter can reduce scheduled maintenance calls by up to 50%

Specifications

Serinus 30 Trace CO analyzer


Range:

LDL:

Noise:

Temperature range:

Sample flow rate:

Weight:

 

Dimensions:

Power:

0-100 ppm

< 20 ppb with Kalman filter active

< 10 ppb with Kalman filter active

0 to 40°C

1000 cc/min

17.8 kg (bench)

12.8 kg (rack)

440 x 178 x 620 mm (w x h x d), 3.5 RU

99-132 VAC, 198-264 VAC 47-63 Hz

Data Logging:

  • Internal memory that stores data in the following formats:
  • Instantaneous data from: 1, 3, 5, 10, 30, or 60 minute intervals
    • Average data from: 1, 3, 5, 10, 15, 30 minutes, 1, 4, 8, 12, or 24 hours
    • Data storage of 8 years, 1 minute data on 1 gigabyte memory


Accessories

Serinus 30 Trace CO analyzer

Accessories

Pt No.

Rack mount kit assembly (19”) E020102
Internal low power pump (Max 6 watts) E020107
External PUMP 230/240 VAC/50Hz P030004
External PUMP 110/115 VAC/60 Hz P030005
Dual sample filter (installed) E020100
Bench top lid (installed) E020110
High pressure calibration (installed) E020108 (Span)
E020109 (Zero)

Spares/Consumables

Pt No.

CO to CO2 converter assembly H014130
Infrared source H014201
Particulate filter (50 p.ce) F010004
Annual Maintenance Kit E020202
Spring compression H010040
Orifice, 14 mil H010043-13
Gasket, pressure sensor H010037
Extraction tool orifice and filter H010046
Detector S030005
Motor, Opto, Lamp, Correlation wheel assembly H014125

Downloads

General Downloads

Brochure - Serinus 30 Trace CO analyzer



Customer Downloads (must be logged in)

Serinus Downloader software


find-distributor_small

FIND OUT MORE