CO analyzer

Overview

Serinus 30 CO analyzer

The new Serinus 30 CO analyzer is the next generation in gas monitoring technology.

co analyzer serinus

The Serinus 30 CO analyzer uses proven gas filter correlation technology to measure CO in ambient air (LDL <40 ppb, Range 0-200 ppm). Combining several new technical advances and innovative features, the Serinus delivers Ecotech's renowned performance and excellent value.

 

The Serinus 30 CO analyzer is designed with modern technology and contains advanced communications for use in remote communication and instantaneous data display on the internet.

  • U.S. EPA approval (EQOA80987) along with EN approval (Sira MC 100166/00)
  • More affordable to purchase, operate and maintain
  • New zero volume fittings and flexible Teflon tubing improves system integrity
  • New intuitive menu system with quick menu
  • Internal memory stores 8 years of data
  • Reduced power usage, lower carbon footprint
  • Improved remote instrument diagnostics and maintenance functions
  • New dual particulate filter can reduce scheduled maintenance calls by up to 50%

EC9830 CO analyzer

The EC9830 CO analyzer is Ecotech's original CO analyzer with 20 years active use within the market.

co analyzer ec9830

The EC9830 CO analyzer combines microprocessor control with gas filter correlation technology to provide accurate measurements of CO in the range of 0-200 ppm with a detection limit of 50 ppb.

 

The EC9830 CO analyzer is most suited to applications that require internal zero/span or for those with previous 9800 series CO analyzers.

  • U.S. EPA approved (EQOA-0193-091)
  • Internal pump option available
  • Internal zero and span available
  • Optional internal 12VDC power supply enables the CO analyzer to be operated from a battery or solar powered source for remote or mobile applications.
  • External remote control of the CO analyzer (provides up to 100 channels of instrument operating parameters)
  • Data accessed via RS232, USB interface or optional Ethernet connector

Specifications

Serinus 30 CO analyzer


Range:

LDL:

Noise:

Temperature range:

Sample flow rate:

Weight:

 

Dimensions:

Power:

0-200 ppm

< 40 ppb with Kalman filter active

< 20 ppb with Kalman filter active

0 to 40°C

1000 cc/min

17.8 kg (bench)

12.8 kg (rack)

440 x 178 x 620 mm (w x h x d), 3.5 RU

99-132 VAC, 198-264 VAC 47-63 Hz

Data Logging:

  • Internal memory that stores data in the following formats:
  • Instantaneous data from: 1, 3, 5, 10, 30, or 60 minute intervals
    • Average data from: 1, 3, 5, 10, 15, 30 minutes, 1, 4, 8, 12, or 24 hours
    • Data storage of 8 years, 1 minute data on 1 gigabyte memory


EC9830 CO analyzer

Range:

LDL:

Noise:

Temperature range:

Sample flow rate:

Weight:

 

Dimensions:

Power:

0-200 ppm

50 ppb with Kalman filter active

25 ppb with Kalman filter active

5 to 40oC

1000 cc/min

22 kg (A series)

21.8kg (B series)

440 x 178 x 620 mm (w x h x d), 3.5 RU

99-132 VAC, 198-264 VAC 47-63 Hz 110 Watts

Data Logging:

  • Supports internal data logging capability with storage up to 175 days of 5 minute data stored in flash ROM

Accessories

Serinus 30 CO analyzer

Accessories

Pt No.

Rack mount kit assembly (19”) E020102
Internal low power pump (Max 6 watts) E020107
External PUMP 230/240 VAC/50Hz P030004
External PUMP 110/115 VAC/60 Hz P030005
Dual sample filter (installed) E020100
Bench top lid (installed) E020110
High pressure calibration (installed) E020108 (Span)
E020109 (Zero)

Spares/Consumables

Pt No.

CO to CO2 converter assembly H014130
Infrared source H014201
Particulate filter (50 p.ce) F010004
Annual Maintenance Kit E020202
Spring compression H010040
Orifice, 14 mil H010043-13
Gasket, pressure sensor H010037
Extraction tool orifice and filter H010046
Detector S030005
Motor, Opto, Lamp, Correlation wheel assembly H014125

EC9830 CO analyzer

EC9830 CO analyzer is available in two versions A series with internal pump, or B series without.

A series

Instrument description Pt No.
EC9830A CO analyzer with internal pump 98301000-100
EC9830A CO analyzer, with internal pump and
high pressure Span valve option
98301000-2
EC9830A CO analyzer, with internal pump and EZS 98301000-5
EC9830A CO analyzer customised 98301000-X

B series

Instrument description Pt No.
EC9830B CO analyzer basic instrument 98307000-1
EC9830B CO analyzer with particulate filter 98307000-3
EC9830B CO analyzer with particulate filter and EZS 98307000-4
EC9830B CO analyzer with EZS 98307000-5
EC9830B CO analyzer customised 98307000-X

* B series only

Accessories

Pt No.

Rack mount kit assembly (19”) 9800036-2
External zero/span valve assembly (EZS) 98000087
USB/Network Adaptor Assembly RJ45 option 98007509-1
12 VDC Internal Power Supply 98000115
Sample particulate filter assembly 98000210-1*
External sample pump 115V 60 Hz P030005*
External sample pump 220V 50/60 Hz P030004*
PCA 50 pin I/O CIR 2015 *

^ A series only * B series only

Spares/Consumables

Pt No.

CO to CO2 converter assembly 98300023
Source IR 80340371
Particulate filter (50 p.ce) 98000098-1
Annual Maintenance Kit 98301000-kit1^
Annual Maintenance Kit 98307000-kit1*
Detector 37000076
Motor Brushless DC 98300032

find-distributor_small

FIND OUT MORE