Data Reporting Software

Overview

Ecotech’s WinCollect 5 is the latest installment of Ecotech's long running WinCollect series of environmental data management software packages. WinCollect 5 is a powerful tool for retrieving, validating and presenting data collected from a variety of environmental monitoring systems. Supporting single or multi user installations WinCollect 5 provides the user with the most stable, streamlined and easy to use package available.
data-report-graphical-windrose

 

WinCollect 5 has advanced data collection capabilities which allow downloading of data from a wide range of industry leading data loggers, through a variety of different methods. WinCollect 5 is able to download from multiple stations simultaneously, downloading data from large monitoring networks in minutes. WinCollect can be scheduled to automatically download data, and when combined with automatic report generation, the entire reporting cycle can be automated.

Features

  • Automates entire data retrieval process
  • Manually or automatically download data from a wide variety of loggers
  • Communicates with most environmental data loggers
  • New "Script Writer" enables customers to easily write their own communication protocol for loggers not supported
  • Modular design providing greater stability and robustness
  • SQL Multi user access

 

 

WinCollect 5’s new data validation facilities makes the validation process simple and easy, in addition to providing advanced auditing functionality.

Data validation in WinCollect allows users to quickly validate/invalidate data and assign a reason for the action being performed. Blocks and entire columns of data can be highlighted and a single common reason assigned to them via a simple drag and drop. This action can also include transformations of data such as offsets, multipliers or even directly editing the value.

Changes to data are highlighted with different colours indicating the changes being made.

All changes are recorded and can be viewed and exported in the Audit tab, this shows the history of every single change, why it changed and who changed it.

Data is also presented as an easy to view dynamic graph which can be zoomed and manipulated multiple ways to get an instantaneous idea of data trends. The graph can be used to plot changed data against original data, allowing a quick visual comparison of both sets

 

Features

  • Data can be easily validated or invalidated with the click of a button
  • Graphical representation of data allows quick visual inspection for outliers and data errors
  • Data can be imported with predefined “ranges” that data must be within or outside to be tagged as valid
  • Changes to data can be viewed in “Audit” tab
  • Changed data highlighted in data table according to what was changed

 

 

 

WinCollect 5 includes a new feature, the Web Display Module. This module allows users to create a website that can automatically update data in real time, download/export data and check data in graphical and raw numerical form. WinCollect 5 displays interactive, dynamic graphs in a number of different formats including:

  • GIS (Geographical information system)
  • Simple XY and scatter plots
  • Wind roses

GIS Geographical information system - Displays data on a map presenting data at each location in real time along with individual station status flags.

 

 

 


Graphical Reports

WinCollect 5’s graphical reporting capabilities allow users to present data in a graphical format in a variety of ways. Data can be presented as Bar graphs, Distribution graphs, Frequency graphs, Polar plots and/or Wind Rose. More advanced graphical reporting is also available through combining with exceedence reports, a pollution index (data points plotted against defined threshold levels) or even a map showing the physical location and direction of pollutants.

Graphical reports can be exported into a Data report as an image file, updated in real-time on a screen or on a website.

 


Data Reports

Data reports display downloaded data in an easy to view format. Data reports are fully customizable and can be tailored to fit in with any organizations existing reporting format. Data reports can report values in numerical format or can combine both numerical and graphical data, providing the user with a powerful reporting program.

Reports are generated via an easy to use wizard, Once a report is generated it can be scheduled to automatically produce the report of a user defined interval. Automatically generated reports can be set to automatically.

  • Download data
  • Generate graphical reports
  • Insert graphs and data into reports
  • Send the report to its destination (website, email, screen etc)

 


Report Types


  • List reports - Formatted text, tables
  • Line, Bar Graphs of
    • Average
    • Maximum, Minimum
    • Standard Deviation
    • Rolling Averages
    • Percentile
    • Log Mean
  • Average Pollution Plots
  • Percentage Pollution Concentrations
  • Frequency Distribution Histogram - linear/logarithmic
  • Cumulative Frequency Distribution Plots - linear/logarithmic
  • Wind Rose, Polar Pollution, Polar Scatter plots
  • Pollution Indices
All graphs and reports are available for any user definable period including hourly, daily, weekly, monthly and yearly periods.

.

  • RS232
  • TCP/IP
  • 3G network
  • Dial up network
  • data file

 



Alarms are generated when data is outside a user defined range and can be sent to send out warning in multiple different formats. Alarms can be activated when pollutants are over exceedence levels, specific weather conditions exist or when an instrument or station is not working.

  • email
  • sms
  • serial port
  • displayed on a monitor

 

 

 

WinCollect is available in multi-user format that allows a number of people to use the program simultaneously, checking data, creating reports and monitoring alarms.

 

  • Allows multiple users to simultaneous access the program
  • Users can be assigned different levels of access
  • Standard or floating licences available

 

 

 

 

Specifications

 

Computer requiriements

Pentium III min

1Gb RAM

MS Windows XP/VISTA/7.0

SVGA Monitor (1024 X 768 or greater)

120Gb Hard Drive min

USB port (for installation of software protection key)

USB Mouse & keyboard


find-distributor_small

FIND OUT MORE