The Ecotech GasCal 1100 gas dilution calibrator performs precise gas dilution calibrations, ozone analyzer precision checks, gas phase titrations and with its optional photometer can be used as an ozone transfer standard. |

The GasCal 1100 gas dilution calibrator uses the latest technology in a simple and effective way to precisely control the dilution of gas standards for calibration of ambient air and source monitoring analyzers. The calibrator may be connected with up to 4 external gas cylinders for precise dilution of these gas standards with dilution air in order to generate a wide range of user configurable gas concentrations sequences.
Gas phase titrations and ozone analyzer precision checks may also be performed using the GasCal 1100 gas dilution calibrators extremely stable optional internal ozone generator. The ozone generator produces a continuous flow of ozone using the photochemical reaction of oxygen with ultraviolet light with a wavelength of 185 nm. The ultraviolet lamp used to stimulate this reaction is maintained at 50.0 °C ±0.1°C by a proportional temperature controller and the ozone flow rate of 100 sccm is kept stable using a precision mass flow controller.
The optional photometer module enables the GasCal 1100 gas dilution calibrator to be used as a transfer standard for calibration of ozone analyzers as well as being able to perform gas dilutions and gas phase titrations. It is suitable for stand alone use or incorporation into an ambient air monitoring system. The photometer accurately and continuously measures the ozone concentration output by the GasCal's internal ozone generator. This ozone is measured and then directed to an ozone analyzer for routine calibration.
|
Input dilution: Input sources: Source MFC: Dilution MFC: Flow accuracy: Operating press: Ozone generator: Weight: Dimensions : Power: |
1 standard 170-200 kPa (g) 1-4 as standard 140-170kPa (g) 0-10 slpm (std), 0-2 or 0-5 slpm (opt) 0-50 sccm (std), 0-20 or 0-100 sccm (opt) Within 1% of full scale 100-200 kPa 50 - 1000 ppb at 3 SLPM 11 kg 440 x 135 x 450 mm (wxhxd), 19" Rack 110-120V or 200-240V AC 50/60 Hz |
GPT Option - Specifications
| Output: | 50 to 1000 ppb at 3 slpm |
| Repeatability: | < 1% short term (24 hours), 5% long term at constant temperature. |
Photometer Option - Specifications
| Ranges: | 0-1000 ppb |
| Linearity: | +/- 2 ppb or + 1% of full scale whichever is greater |
| Precision: | +/- 2 ppb |
| Zero Drift: | +/- 1 ppb 30 days |
| Span Drift: | +/- 2 ppb 30 days |
| Flow rate: | 3 slpm |
| Instrument description | Pt No. |
| GasCal 1100 gas calibrator without internal ozone generator | ECO-GC1100 |
| GasCal 1100 gas dilution calibrator customised | ECO-GC1100X |
| GasCal 1100 gas dilution calibrator with internal ozone generator | ECO-GC1100GPT |
| GasCal 1100 gas dilution calibrator customised | ECO-GC1100GPT-X |
| GasCal 1100 gas dilution calibrator w photometer option | ECO-GC1100PHOT |
| GasCal 1100 gas dilution calibrator w photometer option customised | ECO-GC1100PHOT-X |
|
Accessories |
Pt No. |
| Second source Mass Flow controller | -2MFC |
| Rackmount kit (not sliding) | ECO-RACKKIT |
| Telescopic slidiing tray for GasCal | HAR-2910 |
| Bracket for above sliding tray | HAR-2911 |
| Portable case for GasCal | ECO-GCPORT-1 |
Brochure GasCal 1100 Gas Dilution Calibrator
User Manual - GasCal 1100 gas dilution calibrator user manual